Dinajpur Medical College

Facility Identification

Division: Rangpur

District: Dinajpur

District Code: 27

Facility Type: Government Hospital

Establishment Year: 1992

Type of Hospital: Mixed Hospital

Category: Secondary Level Hospital

Size of the Hospital: The hospital is established on its own land

Patient Information

Patient Type: All types of patients from different ages visit the hospital.

Average number of patients per day: 80

Patient number in last year: 10000

Payment Provided by: Mainly Government and patients.

Equipments and Instruments

By calling tender they buy their instruments and sometimes some donor agency/NGO provides some equipments.

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A OPD  
a Slit Lamp Yes Yes 2
b Schiotz Tonometer Yes Yes 1
c Direct Opthalmoscope Yes Yes 5
d Indirect Opthalmoscope Yes Yes 1
e 90 D lens Yes Yes 2
f 20 D lens Yes Yes 2
g Gonioprism Yes
h Bjerum’s screen Yes
i Hess chart screen Yes Yes 1
j Material for diplopia chart Yes Yes 2
k Red green goggles Yes Yes 1
Refraction
m Snellen test type Yes Yes 2
n Near vision testing(Jaeger or Snellen) Yes Yes 4
o Streak Retinoscope Yes Yes 4
p Trial Frame and trial case Yes Yes 3
q Prism bar Yes Yes 1
r Refractometer Yes Yes 1
s A-scan Yes Yes 1
t Keratometer Yes Yes 1
B Advancer secondary eye care  
a FFA including Fundus camera Yes Yes 1
b YAG Laser with slit lamp adapter Yes Yes 1
c Laser unit for retinal coagulation Yes Yes 1
d Exophthalmometer Yes
e B-Scan Yes Yes 1
C OT  
a Operating Microscope with co-axial illumination & focus control Yes Yes 1
b PHACO Machine Yes Yes 1
c Automated Vitrectomy Yes
d Bipolar Cautery Yes Yes 1
e Steam Autoclave Yes Yes 1
f Flash/Speed Autoclave Yes
g Suction Machine Yes Yes 1
h Oxygen Cylinder with nasal canula Yes Yes 2
i Endotracheal intubation Yes Yes 1
j Ambu bag Yes Yes 1
k Laryngoscope Yes
l BP Machine Yes Yes 4
m Stethoscope Yes Yes 3
Surgical Instruments
o Cataract surgical sets Yes Yes 2
p DCR set Yes Yes 2
q Chalazion I/C set Yes Yes 2
r Enucleation and Evisceration set Yes Yes 2
D Optical dispensing instruments  
a Manual Edging set Yes Yes 1
b Rimless & Supraframes grooving machine Yes Yes 1
c Lensometer Yes Yes 1
d Trial set (Manual power check) Yes P

 

2

Human Resources

Total Human Resources: 28

Senior Ophthalmologist: 1

Junior Ophthalmologist: 1

Refractionist: 1

Optometrist: 1

Outpatient Nurse: 3

Ward Nurse: 2

Theatre Nurse: 3

Name of the Ophthalmologists: 1. Dr. Habibur Rahman Hiru

  1. Dr. Rafiqul Hoque

Professional Degree: Diploma in Ophthalmology, MS, FCPS

Professional Training: Pediatric Ophthalmology-12 months

Administrative Human Resources:

Administrator: 1

Eye Camp Coordinator: 1

Administrative support staff: 2

House Keeper: 2

Cl

Biomedical/Equipment Technician eaner: 4

Driver: 2

Security Staff: 2: 1

Counselor: 1

Record keeping System: Both papers and computers in

Service Area

This hospital provides diagnosis services.

Provided Services:

  1. Refractive Error
  2. Cataract
  3. Glaucoma
  4. Trauma
  5. Lacrimal Surgery
  6. Medical Strabismus

Referral System: They refer their patients to the specialized hospitals for complicated cases. Especially for the complicated pediatric cases. But they do not do anything to send the patients to the referred organizations. They cannot do follow up the patient properly.

Number of Cataract Operation in last 2 weeks: 15

Workload Estimation

Number of Beds in Hospital: 25

Effective Days for providing services: 300

Surgery per year: 650

Patients per year in outdoor: 20000

New patients per day: 40

 

Infrastructure

They have OT and OPD, IPP including medical records, optical shop and medical shop. They have 2 wards and 12 dedicated beds for eye department. and the average number of operation is 3 per day in this hospital. Size of the ward is 2500 sq ft and the office area is 1000 sq ft. According to them their hospital’s cleanliness is very good and they have continuous water and electricity supplies but they do not have gas supply.