Chittagong Eye Infirmary and Training Complex

Facility Identification

DSC_2858-1

 

 

 

 

Division: Chittagong

District: Chittagong

District Code: 15

Facility Type: Non Government Hospital

Type of Hospital: Eye Hospital

Year of Establishment: 1983

Category: Tertiary Level Hospital

Size of the Hospital: 8 Acre

 

Detail Information of the facility - Patient Information

All types of patients come here to take treatment for their eye diseases.

Average number of patients per day: 1000

Patient number in last year: More than 2 Lakhs

Detail Information of the facility - Human Resources

Total Human Resources: About 400

Senior Ophthalmologist: 20

Junior Ophthalmologist: 15

Refractionist: 15

Optometrist: 7

Ward Nurse: 2

Theater Nurse: 3

Administrative Human Resources:

Administrator: 5

Eye Camp Coordinator: 1

Administrative Support Staff: 5

House keeper: 6

Cleaner: 15

Driver: 10

Security Staff: 12

Counselor: 5

Record keeping System: Both in papers and in computers.

Clinical Service Area

  1. Retina
  2. Glaucoma
  3. Cornea
  4. Surgical Cataract
  5. Pediatric
  6. Uvea
  7. Orbit
  8. General OPD
  9. Refractive error and General Ophthalmology
  10. Low Vision

Other facilities provided by Hospital

  1. Research
  2. Eye Bank
  3. Biomedical Engineering Department
  4. Microbiology
  5. Pathology and clinical biochemistry
  6. Housekeeping services and dietary services
  7. Opticals and Medicals

Systems and Procedures

  1. Clinical Protocols & guidelines
  2. Clinical Audit
  3. Counseling section
  4. Procurement Policy
  5. HR Policy
  6. Color coded waste management

Space Management

Size of the Reception Room: 2000 sq ft

Size of the Scraping room: 200 sq ft

Cornea - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A Slit Lamp yes
B Corneal topography unit yes yes
C Aberrometry assessment unit
D Specular microscope yes
E Light microscope yes
F Basic microbiology instruments yes
G LASIK (Optional) yes

Cornea - Human Resources

  1. Cornea Consultant-2
  2. MLOPs (OPD, OT, ward)- 1
  3. Technician for topography/ specular microscope-1
  4. Counselor-1

Eye Bank - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A Refrigerators – 260 liter capacity (Frost Free) yes
B Topcon Slit lamp yes
C Laminar Air Flow hoods yes
D Enucleation sets yes
E Excision sets yes
F Specular Microscope – Konan EKA-10 with software yes
G Autoclave yes
H Stainless Steel Bins/Trays yes
I U.V. lamps with fittings 4 sets yes
J Thermometer yes
K Computer with printer yes
L Furniture’s & Filing cabinets yes
M Air – Conditioning (1.0 T) yes
N Room Partition work yes
O Blood testing equipments for serology yes

Cornea - Human Resources

Board of Directors-2

Medical Director-1

Executive Director-1

Eye Bank Manager-1

Eye Bank Technicians-2

Eye Donations Counselors-2

Administrative Secretary-1

Panel of Registered Medical Practitioners to enucleate round the clock-4

This Department has separate Front Office, Reception, Tissue processing lab, Instrument maintenance room and Cornea preparation and shipping area.

The size of the Eye bank department 600 sq ft.

Glucoma - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A Slit Lamp yes
B Goldmann Applanation tonometry yes
C Diagnostic lenses (90 D, 20D, 78D) yes
D Gonioscope yes
E Perkins tonometer yes
F Pachymetry yes
G Humphrey Visual Field Analyzer yes
H Heidelberg retinal tomography (HRT)- shared yes
I Optical coherence tomography (OCT)-shared yes
J Anterior segment OCT yes
K Ultrasound biomicroscope-shared yes
L YAG Laser for glaucoma surgery-shared yes
M Fundus photography-shared yes

Glucoma - Human Resources

  1. Ophthalmologist-2
  2. Paramedical Staff-2
  3. Couselor-1
  4. Optometrist-1

Glucoma - Space Requirement

Humphrey Visual Field Analyzer-2

Size of the Humphrey Visual Field Analyzer-120 sq ft

Size of the GDx and (or) OCT-120 sq ft

How many Yag PI- 1

Size of the Yag PI- 100 sq ft

Size of the total waiting area-150 sq ft

Low Vision Clinic - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A Optical Aids for distance
a Telescopes 3x,4x,6x yes
B Optical Aids of near spectacle magnifiers
a Prismosphere +5.0D, +8.0D, +10.0D yes
b High spherical glasses +16.0D, +18.0D, +24.0D yes
c Hand Magnifiers: Illuminated yes
d Hand Magnifiers: Non Illuminated yes
e Stand Magnifiers: Illuminated yes
f Stand Magnifiers: Non Illuminated yes
C Non Optical Aids
a Typoscopes yes
b Bold Tip Black Pens yes
c Table Light yes
d CCTV yes
e Telescopes 3x,4x,6x yes

Low Vision Clinic - Human Resources

  1. Ophthalmologist-1
  2. Optometrist-2
  3. Rehabiitationist-1
  4. Administrator-1
  5. Mobility instructors- 1
  6. Psychologists-1

Low Vision Clinic - Space Requirement

Size of the Registration Optical & Dispensing room 65 sq ft

Size of the Refraction (Cyber chart) room 40 sq ft

Size of the Low vision assessment room 50 sq ft

Size of the Counseling room 40 sq ft

Size of the Vision Stimulation room 60 sq ft

Pediatric Ophthalmology - Human Resources

  1. Pediatric Ophthalmologist-2
  2. Fellow-2
  3. Orthoptist -1
  4. Refractionist- 2
  5. OPD Nurse-4
  6. Conselor-2
  7. Ward Nurse-2
  8. Coordinator-1
  9. Anesthetist- 2
  10. OT Nurse-2
  11. Technician- 1

Pediatric Ophthalmology - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A Outpatient Area
a Sheridan Gardiner test/ Cambridge simple crowding test yes
b Simple Snellen Visual acuity charts- drum yes
c Cardiff Card yes
d Set of trial lenses with trial frame yes
e Streak retinoscope yes
f Direct ophthalmoscope yes
g Head-band loupe yes
h Slit lamp with table & applanation tonometer yes
i 90 D or 78 D lens yes
j Ishihara color vision book yes
k Indirect ophthalmoscope with +20D /+30D lens, pediatric indentor and teaching mirrors yes
l Fixation toy device yes
m Romanes Occluder yes
n Air Puff Tonometer yes
o Tonopen yes
p Worth 4 dot test set with Red and Green glasses – Near vision yes
q Worth 4 dot test set with Red and Green glasses – distance vision yes
r TNO stereo test set with Red and Green glasses. yes
s Electric Hess screen with fosters torches yes
t Loose prism set yes
u Prism bar – horizontal yes
v Prism bar – vertical yes
w RAF ruler yes
x Synoptophore yes
y B-Scan yes
z A-scan yes
Aa ILO Master Biometry yes
Operating Room
Bb Probing set yes
Cc Instruments for examination Under GA yes
Dd Ptosis surgical instrument set yes
Ee Enucleation surgical instrument set yes
Ff Chalazion surgical instrument set yes
Gg Strabismus surgical instrument set yes
Hh Cataract/Phaco surgical instrument Set   yes  
Ii Vertical/Horizontal autoclave with Time/Pressure/Temperature indicator yes
Jj Flash/Speed autoclave/Hot air woven yes
Kk Wet field cautery yes
Ll HEPA Filters/ Laminar Air Flow yes
Mm Operating Microscope with continuous zoom, observer scope/CCTV yes
Nn Phaco machine with in-built vitrectomy probe yes
Oo Vitrectomy unit yes
B Anesthetic Equipments
a Anesthesia Unit yes
b Patient monitor with pulse oximetry, blood pressure measurements, ECG, Temperature, capnography suitable for age range of children yes
c Pediatric ventilator yes
d Defibrillator yes
e Laryngeal Mask Airway (LMA) yes
f Suction Machine yes
C Optical Workshop Equipment
a Automatic lensometer yes
b Edging machine
c Surfacing Machine yes

Retina - Human Resources

  1. Retina Consultant-6
  2. Fellow-3
  3. MLOPs-3
  4. Refractionist-3
  5. FFA/OCT Technician-5
  6. Counselor-1
  7. Receptionist-1

Retina - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
a Slit lamps yes
b Indirect ophthalmoscopes yes
c Lens 90D yes
d Lens 20D yes
e Three mirror lens yes
f Applanation tonometer
G Noncontact tonometer yes
H Fundus camera yes
I OCT yes
J Ultrasonography yes
K Vitrectomy unit yes
L Operating microscope yes
m BIOM yes
N Boyle’s apparatus yes
O Suction apparatus yes
P ERG (optional) yes

Retina - Space Requirement

Size of the reception room- 60 sq ft

Size of Common waiting area (OPD/FFA/LASER)-160 sq ft

Size of Preliminary examination room-160 sq ft

Size of FFA room 150 sq ft

Size of the OCT room 150 sq ft

Size of the Final examination room160 sq ft

Size of the Laser room 200 sq ft

Size of the Counseling room 130 sq ft

Uvea - Human Resources

  1. Uvea Consultant-1
  2. Vision Assessor- 2
  3. Refractionist-2
  4. Technician (FFA/B Scan/OCT): shared with retina- 4

Uvea - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
a Slit lamp yes
b Slit lamp with camera yes
c Indirect ophthalmoscope with photographic camera yes
d +20D condensing lens yes
e +90D lens yes
f Gonio lens yes
g Goldman’s applanation tonometer yes
h Fundus camera for florescein angiography and ICG (shared) yes
i Ultrasonography machine with B-scan (Shared) yes
j Frequency doubled YAG laser (shared) yes
k Non-mydriatic fundus camera (shared) yes
l OCT (shared) yes
m Non contact tonometer (shared) yes
n Laser flare photometer (optional) yes
o Boyle’s apparatus (shared) yes
p Phaco-Vitrectomy console (shared) yes
q Endo illuminator (shared) yes
r Operating microscope, BIOM (shared) yes
s Suction apparatus (shared) yes

Uvea - Space Requirement

Size of common waiting area- 1500 sq ft

Size of the Uvea Area- 1400 sq ft

Size of the counseling room- 1000sq ft

Adult Cataract - Human Resources

Senior Ophthalmologist-1

Junior Ophthalmologist-1

Out Patient nurse- 10

Ward Nurse-5

Adult Cataract - Equipments

Sl No Equipments Available Functioning Total Number
Available and observed Available but not observed Not Available Yes No Don’t Know
A OPD
a Slit Lamp yes
b Schiotz Tonometer yes
c Direct Ophthalmoscope yes
d Indirect Ophthalmoscope yes
e 90 D lens yes
f 20 D lens yes
g Gonioprism yes
h Applanation tonometer yes
Refraction
i Snellen test type yes
j Near vision testing yes
k Streak Retinoscope yes
l Trial frame and trial case yes
m Prism bar yes
n Refractometer yes
o A-Scan yes
P IOL-Master Biometry yes
q Keratometer yes
B OT
a Operating Microscope with co-axial illumination & focus control yes
b PHACO Machine yes
c Automated Vitrectomy yes
d Bipolar Cautery yes
e Steam Autoclave yes
f Flash/Speed Autoclave yes
g Suction Machine yes

 

Adult Cataract - Space Requirement

OPD Room-5

Size of the OPD Room-8000sq ft

Theatre Area-6